Product Categories
- +Pipeline Fluid System
- Fastener series
- Steel Pipe Series
- Gasket
- elbow Series
- Malleable iron casting
- tee
- Groove parts series
- Reducer and cap series
- Miscellaneous accessories series
- flange series
- Idler series
- Forged pipe fittings series
- Alloy product series
- section steel series
- Prefabrication of steel structures
- Prefabrication of pipelines and pipe fittings
- 3PE
- Coating series
- Hot dip galvanized series
- Wear-resistant series
- Welding series
- +UL Listed Products
- +Alarm System
- +High Pressure Water Mist System
- Mobile Atomization Fire Extinguishing Equipment
- Project System Products
- Pump system
- +Fire Sprinkler System
- Dry Sprinkler
- Water curtain nozzle
- Water mist nozzle
- Fire Sprinkler Escutcheon Plate
- Dry Alarm Valve
- Wet alarm valve
- Deluge alarm valve
- Pre-Action Alarm Device
- Water flow indicator
- Standard Fire Sprinklers
- Extend Coverage Fire Sprinkler
- Concealed Fire Sprinkler
- Storage ESFR Fire Sprinkler
- Standard Fusible Alloy Fire Sprinkler
- +Fire extinguisher
- Fire Hydrant
- +Euro Standard Alarm System
- +Industrial alarm system
- +Industrial Fire Monitor
- fire cabinet system
- +UL SPRINKLER SYSTEM
- Battery fire extinguishing agent
- Fire Hose
- +Fire Monitor System
- +Fire Fighting Valve
- +Foam System
S-type hot aerosol fire extinguishing device


Product Introduction
1. The small thermal aerosol fire extinguishing device is suitable for use in confined spaces. It features a compact size, simple installation, zero maintenance, and low cost. It can be activated either hot or electrically.
2. When the small thermal aerosol fire extinguishing device receives an activation signal, the aerosol generator within the cartridge is activated, decomposing the chemical coolant layer above it, allowing the aerosol generator and coolant to jointly extinguish the fire.
Applications
The small aerosol fire extinguishing device is primarily suitable for use in critical equipment cabinets such as substations, electronic equipment rooms, generator rooms, uninterruptible power supply (UPS) rooms, communications rooms, high and low voltage distribution cabinets, signal base station cabinets, and cable shafts.
Technical Parameters
| Model Specifications | QRR0.01G/S-BA | QRR0.02G/S-BA | QRR0.03G/S-BA | QRR0.04G/S-BA | QRR0.08G/S-BA | QRR0.1G/S-BA | QRR0.15G/S-BA | QRR0.2G/S-BA | QRR0.25G/S-BA | QRR0.3G/S-BA | QRR0.5G/S-BA |
|---|---|---|---|---|---|---|---|---|---|---|---|
| Protected Space (m³) | 0.1m³ | 0.2m³ | 0.3m³ | 0.4m³ | 0.8m³ | 1m³ | 1.5m³ | 2m³ | 2.5m³ | 3m³ | 5m³ |
| Spray Time | ≤20s | ≤40s | |||||||||
| Operating Temperature Range | -45°C~+90°C | ||||||||||
| Nozzle Thermal Distance | Temperature ≤200°C 350mm from nozzle | ||||||||||
| Casing Surface Temperature | ≤200°C | ||||||||||
| Start Method | Electric start or hot start | ||||||||||
| Electric Start Current | ≥500mA | ||||||||||
| Hot Start Temperature | 175°C±15°C | ||||||||||
| Feedback Signal | Passive switching signal | ||||||||||
| Validity Period | 10 years | ||||||||||